Age | Commit message (Collapse) | Author | Files | Lines |
|
|
|
|
|
|
|
It's not needed after 69d823e5710a.
Found by Clang Static Analyzer.
|
|
|
|
|
|
This commit supports variable in the "share" option, the finding path to
file serve is the value from "share". An example:
{
"share": "/www/data/static$uri"
}
|
|
|
|
|
|
Minimal image now uses Debian 11 "Bullseye" as a base.
Language versions are bumped to:
- Go 1.17
- Node 16
- Perl 5.34
- Ruby 3.0
|
|
Because the configuration values were read from the listener's configuration,
an established WebSocket connection was unable to work properly (i. e. stuck)
if the listener was removed. The correct source of configuration values is the
request config joint.
This is related to issue #581 on GitHub.
|
|
Explicitly using the sysconf() call to obtain the minimum thread stack size
instead of the PTHREAD_STACK_MIN macro.
This closes #576 PR on GitHub.
|
|
Since the "pass" option supports both strings and variables, a generic
nxt_var_t structure can be used in the configuration phase, and the "name"
field in actions is redundant.
No functional changes.
|
|
|
|
Deduplicated code and improved style.
No functional changes.
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
No functional changes.
|
|
|
|
|
|
|
|
This commit introduces the replacement of the client address based on the value
of a specified HTTP header. This is intended for use when Unit is placed
behind a reverse proxy like nginx or a CDN.
You must specify the source addresses of the trusted proxies. This can be
accomplished with any valid IP pattern supported by Unit's match block:
["10.0.0.1", "10.4.0.0/16", "!192.168.1.1"]
The feature is configured per listener.
The client address replacement functionality only operates when there is a
source IP match and the specified header is present. Typically this would be
an 'X-Forwarded-For' header.
{
"listeners": {
"127.0.0.1:8080": {
"client_ip": {
"header": "X-Forwarded-For",
"source": [
"10.0.0.0/8"
]
},
"pass": "applications/my_app"
},
}
}
If a request occurs and Unit receives a header like below:
"X-Forwarded-For: 84.123.23.23"
By default, Unit trusts the last rightmost IP in the header, so REMOTE_ADDR
will be set to 84.123.23.23 if the connection originated from 10.0.0.0/8.
If Unit runs behind consecutive reverse proxies and receives a header similar
to the following:
"X-Forwarded-For: 84.123.23.23, 10.0.0.254"
You will need to enable "recursive" checking, which walks the header from
last address to first and chooses the first non-trusted address it finds.
{
"listeners": {
"127.0.0.1:8080": {
"client_ip": {
"header": "X-Forwarded-For",
"source": [
"10.0.0.0/8"
]
"recursive": true,
},
"pass": "applications/my_app"
},
}
}
If a connection from 10.0.0.0/8 occurs, the chain is walked. Here, 10.0.0.254
is also a trusted address so the client address will be replaced with
84.123.23.23.
If all IP addresses in the header are trusted, the client address is set to
the first address in the header:
If 10.0.0.0/8 is trusted and "X-Forwarded-For: 10.0.0.3, 10.0.0.2, 10.0.0.1",
the client address will be replaced with 10.0.0.3.
|
|
|
|
|
|
|
|
|
|
|
|
A crash would occur when the router tried to match an
against an empty address pattern array.
The following configuration was used to reproduce the
issue:
{
"listeners": {
"127.0.0.1:8082": {
"pass": "routes"
}
},
"routes": [
{
"match": {
"source": []
},
"action": {
"return": 200
}
}
]
}
|
|
|
|
In the case that routes or upstreams is empty and the pass option is a variable.
If the resolved pass is routes or upstreams, a segment error occurred.
|
|
Found by Clang Static Analyzer.
|
|
When processing a restart request, the router sends a QUIT message to all
existing processes of the application. Then, a new shared application port is
created to ensure that new requests won't be handled by the old processes of
the application.
|
|
No functional changes.
|
|
No functional changes.
|
|
No functional changes.
|
|
|
|
When a client sends no SNI is a common situation. But currently the server
processes it as an error and returns SSL_TLSEXT_ERR_ALERT_FATAL causing
termination of a current TLS session. The problem occurs if configuration has
more than one certificate bundle in a listener.
This fix changes the return code to SSL_TLSEXT_ERR_OK and the log level of a
message.
|
|
To support TLS sessions, Unit uses the OpenSSL built-in session cache; the
cache_size option defines the number sessions to store. To disable the feather,
the option must be zero.
|
|
This commit fixes a rare crash that can occur when File.write is
called by many threads.
|
|
Unit's ASGI implementation creates a new event loop to run an application for
each thread since 542b5b8c0647. This may cause unexpected exceptions or
strange bugs if asyncio synchronisation primitives are initialised before the
application starts (e.g. globally).
Although the approach with a new event loop for the main thread is consistent
and helps to prepare the application to run in multiple threads, it can be a
source of pain for people who just want to run single-threaded ASGI
applications in Unit.
This is related to #560 issue on GitHub.
|
|
An ASGI application can cancel the Future object returned by the receive()
call. In this case, Unit's ASGI implementation should not call set_result()
because the Future is already handled. In particular, the Starlette framework
was noted to cancel the received Future.
This patch adds a done() check for the Future before attempting a set_result().
This is related to #564 issue on GitHub.
|
|
The receive() call never blocks for a GET request and always returns the same
empty body message. The Starlette framework creates a separate task when
receive() is called in a loop until an 'http.disconnect' message is received.
The 'http.disconnect' message was previously issued after the response header
had been sent. However, the correct behavior is to respond with
'http.disconnect' after sending the response is complete.
This closes #564 issue on GitHub.
|
|
A new application thread port message can be processed in the router after the
application is removed from the router. Assertion for this case is replaced by
a condition to store the new thread port until receiving the stop notification
from the application process.
|