summaryrefslogtreecommitdiffhomepage
path: root/test/unit (unfollow)
AgeCommit message (Collapse)AuthorFilesLines
2021-07-29Application restart introduced.Max Romanov1-0/+1
When processing a restart request, the router sends a QUIT message to all existing processes of the application. Then, a new shared application port is created to ensure that new requests won't be handled by the old processes of the application.
2021-07-23Tests: added SNI test without hostname in request.Andrei Zeliankou1-1/+1
2021-07-02Tests: Ruby hooks.Oisin Canty3-22/+46
2021-07-02Tests: run Ruby applications inside temporary directory.Oisin Canty2-3/+20
2021-05-25Go: fixing tests for Go 1.16.Max Romanov2-0/+2
In Go 1.16, the module-aware mode is enabled by default; to fall back to previous behavior, the GO111MODULE environment variable should be set to 'auto'. Details: https://golang.org/doc/go1.16
2021-05-24Tests: test_settings_send_timeout improved.Andrei Zeliankou1-0/+11
Data length adjusts depending on socket buffer size when it's possible.
2021-05-24Node.js: renamed "require_shim" to "loader".Oisin Canty1-3/+3
2021-05-20Tests: Python targets.Oisin Canty1-2/+9
2021-05-12Tests: added test for TLS with IP in SAN.Andrei Zeliankou1-2/+7
2021-05-12Node.js: a shim for overriding "http" and "websocket" modules.Oisin Canty2-5/+29
Also added stubs for Server.address() This was done to prevent crashes in some popular frameworks like express Supports both CommonJS and the new ES Modules system syntax e.g: app.js: const http = require('http') app.mjs: import http from "http" Usage on Node 14.16.x and higher: { "type": "external", "processes": {"spare": 0}, "working_directory": '/project', "executable": "/usr/bin/env", "arguments": [ "node", "--loader", "unit-http/require_shim.mjs" "--require", "unit-http/require_shim", "app.js" ] } Usage on Node 14.15.x and lower: { "type": "external", "processes": {"spare": 0}, "working_directory": '/project', "executable": "/usr/bin/env", "arguments": [ "node", "--require", "unit-http/require_shim", "app.js" ] }
2021-05-05Tests: added tests for openat2() features.Andrei Zeliankou1-0/+32
2021-04-08Tests: preserving unit.log when run without restart.Max Romanov2-6/+35
Introducing "unit.log.Log" class for "unit.log" file management. Moving "findall()" function into TestApplicationProto. Using "os.kill()" to send signals.
2021-04-05Tests: style.Andrei Zeliankou5-30/+40
2021-03-26Tests: SNI.Andrei Zeliankou2-4/+20
2021-03-22Java: upgrading third-party components.Sergey A. Osokin1-1/+1
2021-02-18Tests: added regex check.Andrei Zeliankou1-0/+13
2021-02-10Tests: increased timeout in wait_for_record().Andrei Zeliankou1-2/+2
2021-02-08Tests: added "--restart" option.Andrei Zeliankou1-1/+1
Now Unit do not restart after each test by default.
2021-01-13Tests: waitformount() and waitforunmount() introduced.Andrei Zeliankou1-0/+32
2020-12-21Tests: introduced a separate cache directory for Go builds.Tiago Natel de Moura1-0/+1
The Go compiler can't detect changes to C header files when compiling CGO applications, and then this leads to Go test samples being linked with wrong libunit. This patch creates a new cache directory reused throughout the test suite.
2020-12-15Tests: fixed bug that disabled isolation tests.Tiago Natel de Moura1-1/+1
2020-12-09Tests: TestUnit class removed.Andrei Zeliankou2-38/+1
Prerequisite checks moved to the fixture in conftest.py.
2020-12-09Tests: isolation check moved to the pytest_sessionstart().Andrei Zeliankou4-186/+190
This change eliminates the need for some classes to run Unit one more time before running tests.
2020-12-08Tests: utils module introduced.Andrei Zeliankou2-1/+51
2020-12-06Tests: options moved to the separate class.Andrei Zeliankou14-13/+29
This change is necessary to separate the logic and prevent possible circular dependency.
2020-11-16Tests: fixing tests interrupt in terminal.Max Romanov4-3/+24
KeyboardInterrupt re-raised.
2020-11-10Python: supporting ASGI legacy protocol.Max Romanov1-1/+2
Introducing manual protocol selection for 'universal' apps and frameworks.
2020-11-10Tests: supporting instant app parameters in load().Max Romanov1-9/+13
2020-11-03Tests: force applications to build for JVM 8.Andrei Zeliankou1-0/+1
This change is made to avoid situations when an application is compiled for a version newer than the Java module used.
2020-11-02Java: upgrading 3rd-party components.Max Romanov1-1/+1
2020-10-29Isolation: mounting of procfs by default when using "rootfs".Tiago Natel de Moura1-0/+14
2020-10-28Tests: improving get_application_type() and fixing its name.Max Romanov6-27/+11
This patch also enables multiversion tests running for Java.
2020-10-27Tests: fixed isolation detection.Andrei Zeliankou3-27/+112
2020-10-19Tests: fixed unit.log print.Andrei Zeliankou10-219/+38
2020-10-07Tests: minor fixes.Andrei Zeliankou12-23/+23
2020-10-07Tests: fixed loading selected module version.Valentin Bartenev3-3/+15
Previously, for PHP, Ruby, and Perl the latest version was always loaded in multi-version tests.
2020-10-01Tests: added ASGI WebSocket.Max Romanov1-1/+1
2020-10-01Tests: minor fixes.Andrei Zeliankou8-69/+60
Fixed temporary dir removing. Fixed printing path to log. Module checks moved to the separate file.
2020-09-22Tests: introduced module name configuration.Max Romanov1-3/+10
Also fixed problem with "/" in application name.
2020-09-22Tests: improved response receiving while upgrade.Max Romanov1-4/+1
The patch required to process non-101 response.
2020-09-22Tests: using dict.get() method with default value.Max Romanov1-18/+9
No functional changes. Only code readability improved.
2020-09-16Tests: migrated to the pytest.Andrei Zeliankou14-305/+124
2020-07-28Tests: fixed double stop() call for some tests.Andrei Zeliankou1-6/+11
2020-07-28Tests: style.Andrei Zeliankou2-3/+2
2020-07-22Tests: switching stdout to blocking before printing log.Max Romanov1-3/+6
This is another attempt to fix the following error message: BlockingIOError: [Errno 11] write could not complete without blocking
2020-05-28Tests: Added rootfs tests.Tiago Natel de Moura3-31/+66
2020-05-20Tests: print unit.log in case of errors.Andrei Zeliankou1-1/+2
Thanks to hongzhidao.
2020-05-15Tests: style.Andrei Zeliankou10-19/+26
2020-05-14Configuration: URI encoding in the "pass" option.Valentin Bartenev1-1/+4
This is useful to escape "/" in path fragments. For example, in order to reference the application named "foo/bar": { "pass": "applications/foo%2Fbar" }
2020-04-24Tests: introduced module version specification in prerequisites.Andrei Zeliankou1-2/+14